Semi-detached property, hosted by Richard
Vaillant air source heat pump in a pre 1920 property
Richard
Having installed a heat pump at my own property (https://app.visitaheatpump.com/hosts/158?location=truro) I persuaded a relative to do the same as the savings copmared to LPG are considerable.
Joined the network in 2024
Upcoming events
This host doesn't have an upcoming event at the moment. Ask them to host another one.
Request a visitAbout this property
St Newlyn East, TR8
3 bedrooms
Air source heat pump
Installed by Simon Annear Plumbing and Heating
EPC rating: F
Installing the system
Internal insulation of 70mm was applied to most of the external solid stone walls and loft insulation was increased to 370mm. The system has no difficulty in maintaining the set temperature of 19.5 degrees C.
The installation took 3 days and the installers went to great lengths to ensure that all cabling and pipework is hidden under floor boards and in the roof space.
Living with a heat pump
The LPG gas boiler was replaced in February 2024 with a 5 kW Vaillant aroTHERM Plus system.
Electricity costs are about half the LPG costs as a result of this installation.
Hosted by Richard
Message Richard if you want to ask them something about their heat pump or the process of getting one installed. Click request a visit above if you want to arrange a visit.
Message meAccessing the venue
The host has not added any information about accessing their property